Key Performance Indicator Value Source
L: Location    
L2: Total distance to public transport stop, food service, nearest main residential area, divided by total items. 1000 metres -
E: Energy and Emissions    
E2: Delivered energy in for all operating end uses. 2,7 kWh/m² ua*yr results value
E3: The fraction of total annual operating energy (from E2) provided by on-site renewable energy production. - -
E4: Greenhouse gas from delivered energy for all operating end uses. 33,5 Kg GHG/m² ua*yr corresponding value
M: Materials    
M1: Ratio of usable area to gross area above grade. 70% measurement
M2: Total weight per unit area of all materials in the project. 1650 kg/m3 estimation
W: Water    
W1: Total gross water use per year used for occupants, irrigation and building systems. 0,8 m³ / m² ua*yr results value
W2: Net potable water per year supplied to the project. 0,8 m³ / m² ua*yr results value
I: Indoor Environmental Quality    
I2: Indoor CO2 concentrations for typical occupancies under normal operating conditions. 1000 ppm or less simulation
I3: Indoor TVOC concentrations for typical occupancies under normal operating conditions. formaldehyde 100
toluene 260
xylene 870
mg/m³ or less
measurement after completion
I4: Daylight factor in typical room or space at lowest typical floor. 1,6% simulation
O: Others    
O1: Life cycle cost, or capital cost and actual or estimated operating cost. 62.750 USD measurement after completion