Key Performance Indicator Value Source
L: Location    
L2: Total distance to public transport stop, food service, nearest main residential area, divided by total items. 50 m -
E: Energy and Emissions    
E2: Delivered energy in for all operating end uses. 69 kWh/m2, 63 when renewable energy included -
E3: The fraction of total annual operating energy (from E2) provided by on-site renewable energy production. 10% -
E4: Greenhouse gas from delivered energy for all operating end uses. - -
M: Materials    
M1: Ratio of usable area to gross area above grade. - -
M4: Total weight of re-used/recycled materials in project. 30% -
M5: Fraction of building materials/elements with demounting/recycling instructions.. 5% -
W: Water    
W1: Total gross water use per year used for occupants, irrigation and building systems. 0,104 m3/m2 ua * yr -
W2: Net potable water per year supplied to the project. 0,07 m3/m2 ua * yr -
I: Indoor Environmental Quality    
I1: Statement of conformance to applicable ventilation and air quality standard(s), e.g. ASHRAE, CIBSE, CEN etc.) ASHRAE 62-2007 -
I2: Indoor CO2 concentrations for typical occupancies under normal operating conditions. 800 ppm -
I3: Indoor TVOC concentrations for typical occupancies under normal operating conditions. - -
I4: Daylight factor in typical room or space at lowest typical floor. 99% -
O: Others    
O1: Life cycle cost, or capital cost and actual or estimated operating cost. $260/m2 capital cost including fit-up and soft costs (excluding land) -