Key Performance Indicator Value Source
L: Location    
L2: Total distance to public transport stop, food service, nearest main residential area, divided by total items. 127 metres -
E: Energy and Emissions    
E1: Embodied energy from the total of off-site materials used in construction.  - Inventory of Carbon & Energy (ICE) Version 2.0 
E2: Delivered energy in for all operating end uses. 208 kWh/m² ua*yr estimated project value
E3: The fraction of total annual operating energy (from E2) provided by on-site renewable energy production. 19% PVGIS estimation program JRC
E4: Greenhouse gas from delivered energy for all operating end uses. 90,5 kg GHG/m² ua*yr TERNA 2009
M: Materials    
M1: Ratio of usable area to gross area above grade. 92,60% -
M2: Total weight per unit area of all materials in the project. 2,72 ton/m² ua -
M3: Total weight of renewable materials in project. 6,7 ton/m² ua -
M4: Total weight of re-used/recycled materials in project. 0,7 ton/m² ua -
M5: Fraction of building materials/elements with demounting/recycling instructions. 6% -
W: Water    
W1: Total gross water use per year used for occupants, irrigation and building systems. 1,2 m³ / m² ua*yr -
W2: Net potable water per year supplied to the project. 0,8 m³ / m² ua*yr -
I: Indoor Environmental Quality    
I1: Statement of conformance to applicable ventilation and air quality standard(s), e.g. ASHRAE, CIBSE, CEN etc.) no value (the standard requires the use of filters) UNI 10339
I4: Daylight factor in typical room or space at lowest typical floor. 7% (windows area / sales area) D.M. 5 Luglio 1975
O: Others    
O1: Life cycle cost, or capital cost and actual or estimated operating cost. estimated project value (PV system included): 4.000.000 € -
O2: Other performance information of interest that is not included above or in the performance assessment result. 42 kWp (estimated from project)