Key Performance Indicator Value Source
L: Location    
L2: Total distance to public transport stop, food service, nearest main residential area, divided by total items. 150 metres -
E: Energy and Emissions    
E2: Delivered energy in for all operating end uses. 29,7 kWh/m2 ua * yr (HVAC) UNI EN ISO 832-UNI
10379- L.10/1991 Italy
E3: The fraction of total annual operating energy (from E2) provided by on-site renewable energy production. 48,80% -
E4: Greenhouse gas from delivered energy for all operating end uses. - -
M: Materials    
M1: Ratio of usable area to gross area above grade. 93% -
M2: Total weight per unit area of all materials in the project. 2,3 tonnes/m² ua -
M3: Total weight of renewable materials in project. 0 -
M4: Total weight of re-used/recycled materials in project. 1,5 tonnes/m² ua -
M5: Fraction of building materials/elements with demounting/recycling instructions. 2% -
W: Water    
W1: Total gross water use per year used for occupants, irrigation and building systems. 0,85 m³ / m² ua*yr -
W2: Net potable water per year supplied to the project. 0,18 m³ / m² ua*yr -
I: Indoor Environmental Quality    
I1: Statement of conformance to applicable ventilation and air quality standard(s), e.g. ASHRAE, CIBSE, CEN etc.) no value UNI 10339
I2: Indoor CO2 concentrations for typical occupancies under normal operating conditions. to measure  
I3: Indoor TVOC concentrations for typical occupancies under normal operating conditions. value below the law limit required Dir.2004/42/CE D.Lgs.161/2006
I4: Daylight factor in typical room or space at lowest typical floor. Coop sales area: 30% -
O: Others    
O1: Life cycle cost, or capital cost and actual or estimated operating cost. capital cost: 40.000.000 €