Key Performance Indicator Value Source
L: Location    
L1: Total distance to public transport stop, school, supermarket, divided by total items.  580 metres -
L2: Total distance to public transport stop, food service, nearest main residential area, divided by total items.  507 metres -
E: Energy and Emissions    
E1: Embodied energy from the total of off-site materials used in construction.  21,18 kWh/m² ua*yr Bedec
E2: Delivered energy in for all operating end uses. 120,81 kWh/m² ua*yr CALENER VYP+VERDE
E3: The fraction of total annual operating energy (from E2) provided by on-site renewable energy production. 6,70% VERDE
E4: Greenhouse gas from delivered energy for all operating end uses. 60,41 kg GHG/m² ua*yr VERDE
M: Materials    
M1: Ratio of usable area to gross area above grade. 81,97% -
M2: Total weight per unit area of all materials in the project. 1606,48 kg/m² ua VERDE
M3: Total weight of renewable materials in project. 0 -
M4: Total weight of re-used/recycled materials in project. 0 -
M5: Fraction of building materials/elements with demounting/recycling instructions. 80% VERDE + design documents
W: Water    
W1: Total gross water use per year used for occupants, irrigation and building systems. 2,74 m³ / m² ua*yr VERDE
W2: Net potable water per year supplied to the project. 2,05 m³ / m² ua*yr VERDE
I: Indoor Environmental Quality    
I1: Statement of conformance to applicable ventilation and air quality standard(s), e.g. ASHRAE, CIBSE, CEN etc.) - -
I4: Daylight factor in typical room or space at lowest typical floor. 2,33% VERDE
O: Others    
O1: Life cycle cost, or capital cost and actual or estimated operating cost. 3.032.656 € -