Key Performance Indicator Value Source
L: Location    
L2: Total distance to public transport stop, food service, nearest main residential area, divided by total items. 653 metres -
E: Energy and Emissions    
E1: Embodied energy from the total of off-site materials used in construction. 

7 kWh/m² *yr (Net annualized consumption of embodied energy for envelope and structure)

173 kWh/m² *yr (Net annualized primary embodied energy and annual operating primary energy)

161 kWh/m² *yr (Net annual consumption of primary (source) non-renewable energy for building operations)

 
E2: Delivered energy in for all operating end uses. 128 kWh/m² *yr  
E3: The fraction of total annual operating energy (from E2) provided by on-site renewable energy production. 3,72 kWh/m² *yr (Total on-site renewable energy used for operations)  
E4: Greenhouse gas from delivered energy for all operating end uses. 131,07 kg GHG/m² *yr  
M: Materials    
M1: Ratio of usable area to gross area above grade. 86,43% -
M3: Total weight of renewable materials in project. 32,05 kg/m² ua -
M4: Total weight of re-used/recycled materials in project. 2,7 kg/m² ua -
W: Water    
W1: Total gross water use per year used for occupants, irrigation and building systems. - -
W2: Net potable water per year supplied to the project.

-2.38 m³ / m² *yr (Annual use of grey water for building operations)

4.37 m³ / m² *yr (Net annual consumption of potable water for building operations)

-
I: Indoor Environmental Quality    
I2: Indoor CO2 concentrations for typical occupancies under normal operating conditions. - -
I3: Indoor TVOC concentrations for typical occupancies under normal operating conditions. - -
I4: Daylight factor in typical room or space at lowest typical floor. - -
O: Others    
O1: Life cycle cost, or capital cost and actual or estimated operating cost. 9.720 €/m² (Total present value of 25-year life-cycle cost fot total project) -